b P d W e \ f a l c t d C hp-firmware-smartarray-46a4d957a7 6.64 1.1 Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 firmware This package contains the Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 firmware UK
bldeb6u3x64004
nHewlett-Packard Company 2012 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company Applications/System http://www.hp.com/go/proliantlinux linux x86_64
# create marker files so that we only run hp-fm once per transaction
mkdir -p /var/lib/rpm-state/hp-firmware/
touch /var/lib/rpm-state/hp-firmware/hp-firmware-smartarray-46a4d957a7-6.64-1.1 # clean up our directory
if [ -d "/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-6.64-1.1" ] ; then
rm -rf "/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-6.64-1.1"
fi
if [ -d /etc/hp-firmware/postrm.d ]; then
for i in /etc/hp-firmware/postrm.d/*.sh; do
if [ -r $i ]; then
sh $i
fi
done
unset i
fi
# surface XML so hpsum doesn't need to extract the package
cat<<__ENDCPXML__>>/dev/null
CP026885.scexe
存储设备
Storage
ストレージ
스토리지
儲存裝置
服务器
Server
サーバ
서버
伺服器
Microsoft Windows Server 2008 x64
SUSE LINUX Enterprise Server 10 (AMD64/EM64T)
Red Hat Enterprise Linux 5 Server (x86-64)
SUSE LINUX Enterprise Server 11 (AMD64/EM64T)
Red Hat Enterprise Linux 6 Server (x86-64)
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
VMware vSphere 5.5
VMware ESXi 5.0
VMware vSphere 5.1
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 12
Microsoft Windows Server 2008 R2
VMware vSphere 6.0
固件 - 存储控制器
Firmware - Speichercontroller
Firmware - Storage Controller
Firmware - Controlador de almacenamiento
Micrologiciel - Contrôleur de stockage
Firmware - Controller di memorizzazione
ファームウェア - ストレージ コントローラ
펌웨어 - 스토리지 컨트롤러
韌體 ─ 儲存裝置控制器
Linux (x64)版补充更新 /在线ROM刷新组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m和P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
サプリメンタルアップデート / オンラインROMフラッシュコンポーネント for Linux (x64) - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822
Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822
適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 - Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822
智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822
스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822
Smart Array P220i、P222、P420i、P420、P421、P721m 及 P822
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
English (US), Japanese, German, French, Italian, Spanish
Anglais, Japonais, Allemand, Français, Italien, Espagnol
Englisch, Japanisch, Deutsch, Französisch, Italienisch, Spanisch
Inglese, Giapponese, Tedesco, Francese, Italiano, Spagnolo
英語(US), 日本語, ドイツ語, フランス語, イタリア語, スペイン語
Inglés, Japonés, Alemán, Francés, Italiano, Español
영어(미국), 일본어, 독일어, 프랑스어, 이탈리아어, 스페인어
英语(美国), 日语, 德语, 法语, 意大利语, 西班牙语
美式英文, 日文, 德文, 法文, 義大利文, 西班牙文
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
Updating firmware with rpm installed:
- Install the firmware rpm using the command: rpm -ivh <rpm_filename>. This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location
- The CP026885.scexe script is located in the 'hp-scexe-compat' folder. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above
- To install firmware, you can execute ONE of the following commands:
# ./CP026885.scexe in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)
# ./hpsetup in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
- To uninstall the rpm, run the command: rpm -e <rpm_package_name>, which is the rpm filename without the '.rpm' extension
Updating firmware without installing the rpm:
- Extract the contents of the rpm using the command: rpm2cpio <rpm_filename>.rpm | cpio -id. This extracts the contents of the rpm to 'usr' folder in the current directory
- Navigate to the 'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-*' location and run ./hpsetup to update the firmware. The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above
- The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory
Additional Information:
Installing the firmware rpm package (rpm -ivh) does not update the firmware. It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
- Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
- Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
- Boot from the newly created HP Service Pack for Proliant USB key.
- Follow HP Smart Update Manager steps to complete firmware update.
Online:
- Login as root. (You must be root in order to apply the ROM update.)
- Place the desired firmware to be updated in the directory, /hp/swpackages
- Locate Start.html which is found in the root of the ISO
- Open the html file in a supported browser
- Follow the instructions on the screen
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.64
Last Recommended or Critical Version:
6.64
Previous Version of Firmware:
6.34
Firmware Dependency:
None
Enhancements/New Features:
None
Problems Fixed:
- An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
- When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
Known Issues:
None
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
接続されたSATAドライブによる断続的な中断されたIO要求が、LUN (Logical Unit Number) リセットを起こします。
Px2xコントローラーでSATAドライブを使う場合、サーバーが応答を停止し、コントローラーロックアップ(POST Lockup 0xAB)のために長期間の後、シャットダウンすることがあります。
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB).
]]>
增强功能/新功能:
- 改进了当硬盘生成大量可恢复错误时的错误处理能力。
- 增加了对非热插拔硬盘驱动器的支持。
- 增加了对HP ProLiant Gen9服务器的支持:
- HP ProLiant BL460c Gen9 服务器
- HP ProLiant BL660c Gen9 服务器
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
改善点/新しい機能:
- ハードディスクドライブが多数の回復可能なエラーを生成する時のエラー処理を改善しました。
- 非ホットプラグディスクドライブのサポートを追加しました。
- HP ProLiant Gen9サーバーのサポートを追加しました。
- HP ProLiant BL460c Gen9サーバー
- HP ProLiant BL660c Gen9サーバー
]]>
향상된 기능/새로운 기능:
- 하드 디스크 드라이브가 복구 가능한 오류를 대량 생성하는 경우 오류 처리를 개선했습니다.
- 핫 플러그 이외의 디스크 드라이브에 대한 지원을 추가했습니다.
- HP ProLiant Gen9 서버에 대해 다음과 같은 지원을 추가했습니다.
- HP ProLiant BL460c Gen9 서버
- HP ProLiant BL660c Gen9 서버
]]>
增強或新增功能:
- 已改善硬碟機產生大量可復原錯誤時的錯誤處理。
- 已新增對非熱插拔磁碟機的支援。
- 已新增對 HP ProLiant Gen9 伺服器的支援:
- HP ProLiant BL460c Gen9 伺服器
- HP ProLiant BL660c Gen9 伺服器
]]>
已解决的问题:
- 所有使用2.2 TB或更大的卷配置GPT分区的UEFI系统的严重问题。更多详情,请参阅客户顾问文档#c04602001
- 当一控制器设置为RAID6模式,且系统硬盘驱动器产生大量可恢复错误时,控制器可能进入降级模式并停止运行。在随后重启的加电自检(POST)和在集成管理日志(Integrated Management Log,即IML)中,将显示0x0E错误消息
- 当设置为RAID 6模式时,控制器将向HP智能存储管理器(HP Smart Storage Administrator,即HP SSA)报告0xE0错误,并停止运行
- 驱动器安装在HP ProLiant BL465 Gen8服务器的托架1时,SSD SATA 6G驱动器间歇性发生故障
- 不能修复的ECC错误导致控制器停止响应(锁定0x13)。该版智能阵列固件正确计算要求的最大控制器内存带宽,以承受当前逻辑驱动器配置的流写入操作,并减少不需要最大控制器内存带宽配置下的高速缓存内存速度。当以较低内存数量运行时,消耗较少的功耗,因而性能降级可以忽略。更多详情,请参阅客户顾问文档c03755983
- 与HP ProLiant BL460c Gen9刀片式服务器一起配置时,无法识别HP D2220sb刀片式服务器。更多详情,请参阅客户顾问文档#c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
修正された問題点:
- GPTパーティションで構成された2.2TBより大きなボリュームを使っているすべてのUEFIシステムのクリティカル問題。 詳細についてはカスタマーアドバイザリ# c04602001を参照してください
- コントローラーがRAID6モードに設定され、多数の回復可能なエラーがシステム内のハードディスクドライブによって生成された場合、コントローラーは劣化モードに入り、機能しなくなることがありました。 0x0Eエラーメッセージが、その後の電源再投入のPOST中およびインテグレーテッドマネジメントログ(IML)に表示されました
- RAID 6モードに設定されたときにコントローラーはHP Smart Storage Administrator (HP SSA)に0xE0エラーを報告し機能を中止しました
- ドライブがHP ProLiant BL465 Gen8サーバーのベイ1に構成された場合、断続的にSSD SATA 6Gドライブ障害が発生しました
- 訂正不能ECCエラーが、コントローラーの応答停止を引き起こしました (Lockup 0x13)。 このバージョンのSmartアレイファームウェアは、現在の論理ドライブ構成でストリーミング書き込み操作を維持するために必要な最大のコントローラーメモリ帯域幅を適切に計算し、ピークのコントローラーメモリ帯域幅を必要としない構成で、キャッシュメモリ速度を削減します。 低速のメモリ速度で動作する場合、より少ない電力消費でパフォーマンスの低下はごくわずかであると予想されます。 詳細については、カスタマーアドバイザリ # c03755983を参照してください
- HP ProLiant BL460c Gen9サーバーブレードを構成しているとき、HP D2220sb Storage Bladeは認識されません。 詳細についてはカスタマーアドバイザリ# c04602866を参照してください
]]>
해결된 문제:
- GPT 파티션을 사용하여 구성된 2.2TB 이상의 볼륨을 사용하는 모든 UEFI 시스템에 대한 중요한 문제가 있습니다. 자세한 내용은 고객 권고 # c04602001을 참조하십시오.
- 컨트롤러가 RAID6 모드로 설정되어 있고 시스템의 하드 디스크 드라이브로 인해 복구 가능한 오류가 대량 생성된 경우 컨트롤러가 성능 저하 모드로 전환되고 작동이 중단될 수 있습니다. IML(Integrated Management Log) 및 후속 전원 주기에서 POST 중에 0x0E 오류 메시지가 표시됩니다.
- 컨트롤러가 HP 스마트 스토리지 관리자(HP SSA)에 0xE0 오류를 보고하고 RAID 6 모드로 설정되면 작동을 중단합니다.
- 드라이브가 HP ProLiant BL465 Gen8 서버의 베이 1에 구성되어 있는 경우 일시적 SSD SATA 6G 드라이브 오류가 발생합니다.
- 수정 불가능한 ECC 오류로 인해 컨트롤러의 응답이 중지됩니다(잠금 0x13). 이 버전의 Smart Array 펌웨어는 현재의 논리 드라이브 구성을 사용하여 쓰기 작업 스트리밍 유지에 필요한 최대 컨트롤러 메모리 대역폭을 계산하여 최고 컨트롤러 메모리 대역폭이 필요 없는 구성에 대한 캐시 메모리 속도를 낮춥니다. 더 늦은 메모리 속도로 구동되는 경우 전력이 덜 소모되며 성능 저하는 무시해도 될 것으로 예상됩니다. 자세한 내용은 고객 권고 # c03755983을 참조하십시오.
- HP ProLiant BL460c Gen9 서버 블레이드를 사용하여 구성한 경우 HP D2220sb 스토리지 블레이드가 인식되지 않습니다. 자세한 내용은 고객 권고 # c04602866을 참조하십시오.
]]>
修正的問題:
- 所有設定為使用 GPT 分割區的使用 2.2 TB 或以上磁碟區的 UEFI 系統的重大問題。如需詳細資料,請參閱客戶諮詢 # c04602001
- 當控制器被設為 RAID6 模式並且系統中的硬碟機產生大量可復原錯誤時,控制器可能會進入降級模式並停止運作。在後續關閉接著開啟電源 POST 期間會顯示 0x0E 錯誤訊息並且記錄在整合式管理記錄 (IML) 中
- 設定為 RAID 6 模式時,控制器會報告 0xE0 錯誤至 HP Smart Storage Administrator (HP 智慧型儲存管理員 (HP SSA)) 並且無法運作
- 在 HP ProLiant BL465 Gen8 伺服器的插槽 1 中配置磁碟機時,會間歇性發生 SSD SATA 6G 磁碟機故障
- 無法修正的 ECC 錯誤導致控制器停止回應 (鎖定 0x13)。此版本智慧陣列韌體正確計算運用目前邏輯磁碟機組態來維持串流寫入作業所需的最大控制器記憶體頻寬,並且減少不需要峰值控制器記憶體頻寬的組態的快取記憶體速度。以較慢的記憶體速度執行時,消耗更少的電源且效能的降低可忽略不計。如需詳細資料,請參閱客戶諮詢 # c03755983
- 使用 HP ProLiant BL460c Gen9 刀鋒型伺服器設定 HP D2220sb 儲存刀鋒型伺服器時,無法辨識 HP D2220sb 儲存刀鋒型伺服器。如需詳細資料,請參閱客戶諮詢 # c04602866
]]>
已解决的问题:
- 修复了在HBA模式下在SATA驱动器上运行IO时,罕见的控制器挂起的问题。
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
修正された問題点:
-
HBAモードで、SATAドライブへのIOを実行する場合のまれなコントローラーのハングアップを修正します。
]]>
해결된 문제:
- 드물지만 HBA 모드에서 SATA 드라이브에 IO를 실행할 때 컨트롤러가 중단되는 문제를 해결했습니다.
]]>
修正的問題:
- 修正在 HBA 模式中時執行 SATA 磁碟機 IO 時罕見的控制器當機的問題。
]]>
增强功能/新功能:
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
改善点/新しい機能:
]]>
향상된 기능/새로운 기능:
- 핫 플러그 이외 드라이브에 대한 지원을 추가했습니다.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
已解决的问题:
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
修正された問題点:
-
RAID 6モードに設定されたときにコントローラーはHP Smart Storage Administratorに0xE0エラーを報告し機能を中止しました。
-
HP ProLiant BL465 Gen8サーバーのベイ 1での断続的なSSD SATA 6Gドライブ障害。
-
訂正不能ECCエラーがコントローラーのハングアップを引き起こします(ロックアップ 0x13)。 Smartアレイファームウェアは、現在の論理ドライブ構成でストリーミング書き込み操作を維持するために必要な最大のコントローラーメモリ帯域幅を計算し、ピークのコントローラーメモリ帯域幅を必要としない構成で、キャッシュメモリ速度を削減します。 低速のメモリ速度で動作する場合、より少ない電力消費でパフォーマンスの低下はごくわずかであると予想されます。 詳しくは、以下のURLのカスタマーアドバイザリc03755983を参照してください。 http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
해결된 문제:
- 컨트롤러가 HP Smart Storage Administrator에 0xE0 오류를 보고하고 RAID 6 모드로 설정된 경우 작동을 중단합니다.
- HP ProLiant BL465 Gen8 서버의 베이 1에서 간헐적으로 SSD SATA 6g 드라이브 장애가 발생합니다.
- 컨트롤러 중단을 유발하는 수정 불가능한 ECC 오류(록업 0x13). Smart Array 펌웨어는 현재의 논리 드라이브 구성을 사용하여 쓰기 작업 스트리밍 유지에 필요한 최대 메모리 대역폭을 계산하여 최대 컨트롤러 메모리 대역폭이 필요 없는 구성에 대한 캐시 메모리 속도를 낮춥니다. 더 늦은 메모리 속도로 구동되는 경우 전력이 덜 소모되며 성능 저하는 무시해도 될 것으로 예상됩니다. 자세한 정보는 다음 URL을 통해 제공되는 고객 권고사항 c03755983을 참조하십시오. http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983.
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
6.00 (B)的功能增强/新特性:
- 增加了对SUSE Linux Enterprise Server 12的支持
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
6.00 (B)の改善点/新しい機能:
-
SUSE Linux Enterprise Server 12のサポートを追加しました
]]>
6.00 (B)의 향상된 기능/새로운 기능:
- SUSE Linux Enterprise Server 12에 대한 지원 추가
]]>
適用於 6.00 (B) 的增強或新增功能:
- 已新增對 SUSE Linux Enterprise Server 12 的支援
]]>
6.00 版本修复的问题:
该版固件解决了以下问题:
- 在零内存RAID (ZMR) 模式下运行的系统上执行内核转储(kdump)时,控制器可能停止响应。
- HP智能阵列P420控制器连接到扩展背板和非扩展背板时,控制器不能正确控制SmartCarrier LED指示灯。
- Chkdsk运行缓慢。
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
バージョン6.00で修正された問題:
このファームウェアリリースは、次の問題を解決しました。
-
Zero Memory RAID (ZMR)モードで実行しているシステムでkdumpを実行すると、コントローラーは停止することがあります。
-
HP SmartアレイP420コントローラーがエキスパンダーバックプレーンと非エキスパンダーバックプレーンの両方に接続されたた場合、コントローラーはSmartCarrier LEDを正しく制御しません。
-
Chkdskの実行が遅かった。
]]>
버전 6.00에서 해결된 문제:
이 펌웨어 릴리스에서 다음과 같은 문제가 해결되었습니다.
- Zero Memory RAID(ZMR) 모드에서 실행 중인 시스템에 kdump를 실행할 때 컨트롤러가 정지할 수 있습니다.
- HP 스마트 어레이 P420 컨트롤러가 익스팬더 백플레인 및 비익스팬 더 백플레인 둘 다에 장착되어 있을 때, 컨트롤러가 SmartCarrier LED를 올바로 제어하지 않습니다.
- Chkdsk가 느리게 실행됩니다.
]]>
6.00 版中修正的問題:
此韌體版本已解決下列問題:
- 在零記憶體 RAID (ZMR) 模式中執行的系統上執行 kdump 時,控制器可能會暫停。
- HP Smart Array P420 控制器已連接至擴充背板與非擴充背板,控制器不會適當控制 SmartCarrier LED。
- Chkdsk 執行速度變慢。
]]>
6.00 版本修复的问题:
该版固件解决了以下问题:
- 在零内存RAID (ZMR) 模式下运行的系统上执行内核转储(kdump)时,控制器可能停止响应。
- HP智能阵列P420控制器连接到扩展背板和非扩展背板时,控制器不能正确控制SmartCarrier LED指示灯。
- Chkdsk运行缓慢。
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
バージョン6.00で修正された問題:
このファームウェアリリースは、次の問題を解決しました。
-
Zero Memory RAID (ZMR)モードで実行しているシステムでkdumpを実行すると、コントローラーは停止することがあります。
-
HP SmartアレイP420コントローラーがエキスパンダーバックプレーンと非エキスパンダーバックプレーンの両方に接続されたた場合、コントローラーはSmartCarrier LEDを正しく制御しません。
-
Chkdskの実行が遅かった。
]]>
버전 6.00에서 해결된 문제:
이 펌웨어 릴리스에서 다음과 같은 문제가 해결되었습니다.
- Zero Memory RAID(ZMR) 모드에서 실행 중인 시스템에 kdump를 실행할 때 컨트롤러가 정지할 수 있습니다.
- HP 스마트 어레이 P420 컨트롤러가 익스팬더 백플레인 및 비익스팬 더 백플레인 둘 다에 장착되어 있을 때, 컨트롤러가 SmartCarrier LED를 올바로 제어하지 않습니다.
- Chkdsk가 느리게 실행됩니다.
]]>
6.00 版中修正的問題:
此韌體版本已解決下列問題:
- 在零記憶體 RAID (ZMR) 模式中執行的系統上執行 kdump 時,控制器可能會暫停。
- HP Smart Array P420 控制器已連接至擴充背板與非擴充背板,控制器不會適當控制 SmartCarrier LED。
- Chkdsk 執行速度變慢。
]]>
增强功能/新功能:
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
改善点/新しい機能:
]]>
향상된 기능/새로운 기능:
]]>
增強或新增功能:
]]>
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
103c
323b
103c
3352
103c
323b
103c
3351
103c
323b
103c
3354
103c
323b
103c
3350
103c
323b
103c
3355
103c
323b
103c
3353
103C
323B
103C
3356
CP026885.scexe
Thu, 07 May 2015 01:51:25
1.1
1
True
46a4d957a7
hp-firmware-smartarray-46a4d957a7
46a4d957a7
smartcomponent-linux-firmware-array
hp-firmware-smartarray-46a4d957a7
hp-firmware-smartarray-46a4d957a7
1.1
__ENDCPXML__ + n S aA큤m$$$$$mAm UK
UK
UK
UK
UK
UK
UK
UK
UK
UK
UK
UK
bbda4be7a7dbb4ea4b13dccb66a4ec1c e2f3d47eae8cf979e970f40eff0d4e5a 29f8271714c1e7f8911b87de2700f71c 5e44c63f072cf28837ee24daec0ce296 998e4285fac48d0ae3ad7cd54471a7f3 2cb29cae5b96fe6514aba0c3351a0996 e8b3c6baeaab96d2578e0a704a73a0c0 7b0cec88bf36e6d921c9faaf9afde3a7 b0137853b8f09ec8ae355de1bb3dcab9 69fb2fcf2d93ecdbb7adb8b122862a5f root root root root root root root root root root root root root root root root root root root root root root root root hp-firmware-smartarray-46a4d957a7-6.64-1.1.src.rpm firmware(hp:firmware:3355103c) firmware(hp:firmware:3355103c) firmware(hp:firmware:3350103c) firmware(hp:firmware:3350103c) firmware(hp:firmware:3351103c) firmware(hp:firmware:3351103c) firmware(hp:firmware:3354103c) firmware(hp:firmware:3354103c) firmware(hp:firmware:3352103c) firmware(hp:firmware:3352103c) firmware(hp:firmware:3353103c) firmware(hp:firmware:3353103c) firmware(hp:firmware:3356103c) firmware(hp:firmware:3356103c) firmware(hp:firmware:d2220sb) firmware(hp:firmware:d2220sb) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003352bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003352bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003351bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003351bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003354bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003354bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003350bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003350bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003355bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003355bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003353bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003353bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003356bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003356bc*sc*i*) hp-firmware-smartarray-46a4d957a7 hp-firmware-smartarray-46a4d957a7(x86-64)
@ @ @ @ @ @ @ @ @ @ @ @ @ @ @ rpmlib(VersionedDependencies) /bin/sh /bin/sh /bin/sh rpmlib(PayloadFilesHavePrefix) rpmlib(CompressedFileNames) /bin/sh libc.so.6()(64bit) libc.so.6(GLIBC_2.2.5)(64bit) libc.so.6(GLIBC_2.3)(64bit) libdl.so.2()(64bit) libdl.so.2(GLIBC_2.2.5)(64bit) libgcc_s.so.1()(64bit) libgcc_s.so.1(GCC_3.0)(64bit) libm.so.6()(64bit) libpthread.so.0()(64bit) libpthread.so.0(GLIBC_2.2.5)(64bit) libpthread.so.0(GLIBC_2.3.2)(64bit) libstdc++.so.6()(64bit) libstdc++.so.6(GLIBCXX_3.4)(64bit) libstdc++.so.6(GLIBCXX_3.4.5)(64bit) 3.0.3-1 4.0-1 3.0.4-1 4.8.1 U]U hU@Tl@TG@TFJTD@TCTBV@SϣSR@HP Linux Development 6.64 HP Linux Development 6.34 HP Linux Development 6.34 HP Linux Development 6.12 HP Linux Development 6.10 HP Linux Development 6.10 HP Linux Development 6.00-2 HP Linux Development 6.00-2 HP Linux Development 6.00-2 HP Linux Development 6.00 HP Linux Development 3.58 - An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset.
* When using SATA drives with a Px2x controller, the server may stop responding or shut down after an extended period of time due to a controller lockup (POST Lockup 0xAB). - *Problems Fixed:**
* Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # [c04602001](http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c04602001)
* When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
* The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
* Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
* Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # [c03755983](http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983)
* The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # [c04602866](http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c04602866) - *Enhancements/New Features:**
* Improved error handling when hard disk drives generate a large number of recoverable errors.
* Added support for non-hotplug disk drives.
* Added support for HP ProLiant Gen9 servers:
* HP ProLiant BL460c Gen9 Server
* HP ProLiant BL660c Gen9 Server - *Problems Fixed:**
* Fix for a rare controller hang when running IO to SATA drives when in HBA-mode. - *Problems Fixed:**
* The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
* Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
* Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: