hp-snmp-agents-9.40-2506.36.rhel6.i686
[887 KiB] |
Changelog
by HP Linux Development (2011-03-11):
- ENHANCEMENTS
- Added support to display "N/A" for non reactive thermal sensors instead of "0" value.
- Added support to expose firmware version details for FMP, FPGA and cPLD (XNC) firmware.
- Added support to report USB key/SD card information.
- Provided greater than 2TB physical disk support for smart array and dumb SATA chipsets.
- Added new accelerator error code: "Flash Backed Cache Erasing Flash Memory".
- Added Physical Disk Temperature support.
|
hp-snmp-agents-9.30-2412.31.rhel6.i686
[925 KiB] |
Changelog
by HP Linux Development (2011-03-11):
- ENHANCEMENTS
- Added support to display "N/A" for non reactive thermal sensors instead of "0" value.
- Added support to expose firmware version details for FMP, FPGA and cPLD (XNC) firmware.
- Added support to report USB key/SD card information.
- Provided greater than 2TB physical disk support for smart array and dumb SATA chipsets.
- Added new accelerator error code: "Flash Backed Cache Erasing Flash Memory".
- Added Physical Disk Temperature support.
|
hp-snmp-agents-9.25-2384.10.rhel6.i386
[1.2 MiB] |
Changelog
by HP Linux Development (2011-03-11):
- ENHANCEMENTS
- Added support to display "N/A" for non reactive thermal sensors instead of "0" value.
- Added support to expose firmware version details for FMP, FPGA and cPLD (XNC) firmware.
- Added support to report USB key/SD card information.
- Provided greater than 2TB physical disk support for smart array and dumb SATA chipsets.
- Added new accelerator error code: "Flash Backed Cache Erasing Flash Memory".
- Added Physical Disk Temperature support.
|
hp-snmp-agents-9.20-2350.17.rhel6.i386
[1.2 MiB] |
Changelog
by HP Linux Development (2011-03-11):
- ENHANCEMENTS
- Added support to display "N/A" for non reactive thermal sensors instead of "0" value.
- Added support to expose firmware version details for FMP, FPGA and cPLD (XNC) firmware.
- Added support to report USB key/SD card information.
- Provided greater than 2TB physical disk support for smart array and dumb SATA chipsets.
- Added new accelerator error code: "Flash Backed Cache Erasing Flash Memory".
- Added Physical Disk Temperature support.
|
hp-snmp-agents-9.1.0.57-62.rhel6.i386
[1.2 MiB] |
Changelog
by HP Linux Development (2011-03-11):
- ENHANCEMENTS
- Added support to display "N/A" for non reactive thermal sensors instead of "0" value.
- Added support to expose firmware version details for FMP, FPGA and cPLD (XNC) firmware.
- Added support to report USB key/SD card information.
- Provided greater than 2TB physical disk support for smart array and dumb SATA chipsets.
- Added new accelerator error code: "Flash Backed Cache Erasing Flash Memory".
- Added Physical Disk Temperature support.
|
hp-snmp-agents-9.0.0.48-49.rhel6.i386
[1.8 MiB] |
Changelog
by HP Linux Development (2011-03-11):
- ENHANCEMENTS
- Added support to display "N/A" for non reactive thermal sensors instead of "0" value.
- Added support to expose firmware version details for FMP, FPGA and cPLD (XNC) firmware.
- Added support to report USB key/SD card information.
- Provided greater than 2TB physical disk support for smart array and dumb SATA chipsets.
- Added new accelerator error code: "Flash Backed Cache Erasing Flash Memory".
- Added Physical Disk Temperature support.
|
hp-snmp-agents-8.7.0.23-16.i386
[1.7 MiB] |
Changelog
by HP Linux Development (2010-07-28):
- ENHANCEMENTS
- Added support for the MIBs in the Power Supply Table.
- Added support for the MIB that specifies the version of Insight Management Agents running on the system.
- Added support for the HP NC552m 10Gb 2-port FlexFabric Converged Network adapter.
- FIXES
- Addressed the tape drive not being displayed on the SMH on few configurations.
- Displayed the placement correctly for the failed drive after reboot.
- On Cmax, net-snmp displayed duplicate registration message on the syslog.
- Modifications are done in code to support the HP NC542m for which PCIID information is the same for both the ports.
|