hp-firmware-smartarray-46a4d957a7-6.34-1.1 > t
D H ` p U,wݍd'^x{ė}}P`t7$<|sF8/IK9ϒW9?"7~-r7lQ<)1m%Tlu՝1)P/l&N!@!>3"^*?*@$e"Mҩ&/(*a96K g#2rRL Mٕ4;r*⺤ծ5(J
`[C0$lC3/ݵa$SudZ^HN.֩͝~q9लN6df27450148d2ffa94fcddb9d4e524324531e0aa vn U,vݍd'^6k=qՙc~-QW{dËU|_Z&.-j9fCPU}ҝ_uHFO>0á`rO?iYIKdz46yZq4nf#3Wb4`,j=*5Yh78w\<0EJ#KmN@*x rϗU[Rv'{>1رF9Ho A
!4l 4!Wϙa > 7 h ? X d $ ) - r 7 O c R L | ֔
֬ (
4 d ؠ @ ( 4 ( ] 8 d 9 : > @ G H I X $ Y \ ] @ ^ b d e f l P C hp-firmware-smartarray-46a4d957a7 6.34 1.1 Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 firmware This package contains the Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 firmware U bldeb6u3x64003.SDG THewlett-Packard Company 2012 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company Applications/System http://www.hp.com/go/proliantlinux linux x86_64
# create marker files so that we only run hp-fm once per transaction
mkdir -p /var/lib/rpm-state/hp-firmware/
touch /var/lib/rpm-state/hp-firmware/hp-firmware-smartarray-46a4d957a7-6.34-1.1 # clean up our directory
if [ -d "/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-6.34-1.1" ] ; then
rm -rf "/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-6.34-1.1"
fi
if [ -d /etc/hp-firmware/postrm.d ]; then
for i in /etc/hp-firmware/postrm.d/*.sh; do
if [ -r $i ]; then
sh $i
fi
done
unset i
fi
# surface XML so hpsum doesn't need to extract the package
cat<<__ENDCPXML__>>/dev/null
CP026360.scexe
存储设备
Storage
ストレージ
스토리지
儲存裝置
服务器
Server
サーバ
서버
伺服器
Microsoft Windows Server 2008 x64
SUSE LINUX Enterprise Server 10 (AMD64/EM64T)
Red Hat Enterprise Linux 5 Server (x86-64)
SUSE LINUX Enterprise Server 11 (AMD64/EM64T)
Red Hat Enterprise Linux 6 Server (x86-64)
Microsoft Windows Server 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2012 R2
VMware vSphere 5.5
VMware ESXi 5.0
VMware vSphere 5.1
Red Hat Enterprise Linux 7 Server
SUSE Linux Enterprise Server 12
Microsoft Windows Server 2008 R2
VMware vSphere 6.0
固件 - 存储控制器
Firmware - Speichercontroller
Firmware - Storage Controller
Firmware - Controlador de almacenamiento
Micrologiciel - Contrôleur de stockage
Firmware - Controller di memorizzazione
ファームウェア - ストレージ コントローラ
펌웨어 - 스토리지 컨트롤러
韌體 ─ 儲存裝置控制器
Linux (x64)版补充更新 /在线ROM刷新组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m和P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
サプリメンタルアップデート / オンラインROMフラッシュコンポーネント for Linux (x64) - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822
Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822
適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 - Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822
智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822
스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822
Smart Array P220i、P222、P420i、P420、P421、P721m 及 P822
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
Hewlett-Packard Development Company, L.P.
English (US), Japanese, German, French, Italian, Spanish
Anglais, Japonais, Allemand, Français, Italien, Espagnol
Englisch, Japanisch, Deutsch, Französisch, Italienisch, Spanisch
Inglese, Giapponese, Tedesco, Francese, Italiano, Spagnolo
英語(US), 日本語, ドイツ語, フランス語, イタリア語, スペイン語
Inglés, Japonés, Alemán, Francés, Italiano, Español
영어(미국), 일본어, 독일어, 프랑스어, 이탈리아어, 스페인어
英语(美国), 日语, 德语, 法语, 意大利语, 西班牙语
美式英文, 日文, 德文, 法文, 義大利文, 西班牙文
在运行 Linux 操作系统的目标服务器上更新固件:
- 以根用户身份登录。(必须以根用户身份登录才能应用 ROM 更新。)
- 将 Smart Component 存放到一个临时目录中。
- 在该目录下执行 Smart Component。例如: ./CPXXXXXX.scexe
- 按照 Smart Component 提供的说明执行操作。
- 如要让更新立即生效,请重新启动系统。
如要通过 HP ProLiant 服务包使用 HP 智能升级管理器:
脱机:
联机:
- 以根用户身份登录。(必须以根用户身份登录才能应用 ROM 更新。)
- 将要更新的目标固件放到 /hp/swpackages 目录中
- 找到在 ISO 根位置中发现的 Start.html
- 打开支持的浏览器中的 html 文件
- 按照屏幕上的说明操作
]]>
To update firmware from Linux operating system on target server:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the Smart Component in a temporary directory.
-
From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe
-
Follow the directions given by the Smart Component.
-
Reboot your system if you would like the update to take effect immediately.
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
-
Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
-
Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
-
Boot from the newly created HP Service Pack for Proliant USB key.
-
Follow HP Smart Update Manager steps to complete firmware update.
Online:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the desired firmware to be updated in the directory, /hp/swpackages
-
Locate Start.html which is found in the root of the ISO
-
Open the html file in a supported browser
-
Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the Smart Component in a temporary directory.
-
From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe
-
Follow the directions given by the Smart Component.
-
Reboot your system if you would like the update to take effect immediately.
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
-
Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
-
Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
-
Boot from the newly created HP Service Pack for Proliant USB key.
-
Follow HP Smart Update Manager steps to complete firmware update.
Online:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the desired firmware to be updated in the directory, /hp/swpackages
-
Locate Start.html which is found in the root of the ISO
-
Open the html file in a supported browser
-
Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the Smart Component in a temporary directory.
-
From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe
-
Follow the directions given by the Smart Component.
-
Reboot your system if you would like the update to take effect immediately.
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
-
Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
-
Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
-
Boot from the newly created HP Service Pack for Proliant USB key.
-
Follow HP Smart Update Manager steps to complete firmware update.
Online:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the desired firmware to be updated in the directory, /hp/swpackages
-
Locate Start.html which is found in the root of the ISO
-
Open the html file in a supported browser
-
Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the Smart Component in a temporary directory.
-
From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe
-
Follow the directions given by the Smart Component.
-
Reboot your system if you would like the update to take effect immediately.
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
-
Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
-
Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
-
Boot from the newly created HP Service Pack for Proliant USB key.
-
Follow HP Smart Update Manager steps to complete firmware update.
Online:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the desired firmware to be updated in the directory, /hp/swpackages
-
Locate Start.html which is found in the root of the ISO
-
Open the html file in a supported browser
-
Follow the instructions on the screen
]]>
To update firmware from Linux operating system on target server:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the Smart Component in a temporary directory.
-
From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe
-
Follow the directions given by the Smart Component.
-
Reboot your system if you would like the update to take effect immediately.
To use HP Smart Update Manager from the HP Service Pack for ProLiant:
Offline:
-
Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Utility.
-
Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.
-
Boot from the newly created HP Service Pack for Proliant USB key.
-
Follow HP Smart Update Manager steps to complete firmware update.
Online:
-
Login as root. (You must be root in order to apply the ROM update.)
-
Place the desired firmware to be updated in the directory, /hp/swpackages
-
Locate Start.html which is found in the root of the ISO
-
Open the html file in a supported browser
-
Follow the instructions on the screen
]]>
ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。
-
rootとしてログインします。 (ROMアップデートを適用するにはrootとしてログインする必要があります)
-
Smartコンポーネントをテンポラリディレクトリに置きます。
-
同じディレクトリからSmartコンポーネントを実行します。 例: ./CPXXXXXX.scexe
-
Smartコンポーネントの指示に従います。
-
アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。
HP Service Pack for ProLiantからHP Smart Update Managerを使用するには、以下の手順に従ってください。
オフライン:
オンライン:
-
rootとしてログインします。 (ROMアップデートを適用するにはrootとしてログインする必要があります)
-
アップデートに必要なファームウェアを/hp/swpackagesディレクトリにコピーします。
-
ISOのルートにあるStart.htmlを選択します。
-
htmlファイルをサポートされているブラウザーで開きます。
-
画面の指示に従います。
]]>
대상 서버의 Linux 운영 체제에서 펌웨어를 업데이트하는 방법:
- 루트로 로그인합니다. (ROM 업데이트를 적용하려면 반드시 루트 계정을 사용해야 합니다.)
- 스마트 구성 요소를 임시 디렉터리에 저장합니다.
- 동일한 디렉터리에서 스마트 구성 요소를 실행합니다. 예: ./CPXXXXXX.scexe
- 스마트 구성 요소의 설명에 따라 진행합니다.
- 업데이트를 바로 적용하려면 시스템을 다시 부팅해야 합니다.
HP Service Pack for ProLiant에서 HP Smart Update Manager를 사용하려면:
오프라인:
온라인:
- 루트로 로그인합니다. (ROM 업데이트를 적용하려면 반드시 루트 계정을 사용해야 합니다.)
- 업데이트하려는 펌웨어를 /hp/swpackages 디렉터리에 저장합니다
- ISO의 루트에 있는 Start.html을 찾습니다.
- 지원되는 브라우저에서 html 파일을 엽니다.
- 화면의 설명에 따라 진행합니다
]]>
若要從 Linux 作業系統在目標伺服器上更新韌體:
- 以 root 身份登入。(您必須以 root 身份才能套用 ROM 更新)。
- 請將智慧型元件置於暫存目錄中。
- 從相同的目錄執行智慧型元件。例如: ./CPXXXXXX.scexe
- 請依照智慧型元件所提示的相關指示進行。
- 重新啟動系統,使更新立即生效。
要從 Service Pack for ProLiant (適用於 ProLiant 的服務套件) 中使用 HP Smart Update Manager (HP 智慧型更新管理器):
離線:
線上:
- 以 root 身份登入。(您必須以 root 身份才能套用 ROM 更新)。
- 將想要更新的韌體放入目錄 /hp/swpackages
- 尋找 ISO 的 root 中發現的 Start.html
- 用支援的瀏覽器開啟 html 檔案
- 遵循畫面上的說明
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Deliverable Name:
Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822
Release Version and/or Date:
6.34
Last Recommended or Critical Version:
6.34
Previous Version of Firmware:
6.00
Firmware Dependency:
None
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
Problems Fixed:
Known Issues:
None
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
改善点/新しい機能:
- ハードディスクドライブが多数の回復可能なエラーを生成する時のエラー処理を改善しました。
- 非ホットプラグディスクドライブのサポートを追加しました。
- HP ProLiant Gen9サーバーのサポートを追加しました。
- HP ProLiant BL460c Gen9サーバー
- HP ProLiant BL660c Gen9サーバー
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Enhancements/New Features:
- Improved error handling when hard disk drives generate a large number of recoverable errors.
- Added support for non-hotplug disk drives.
- Added support for HP ProLiant Gen9 servers:
- HP ProLiant BL460c Gen9 Server
- HP ProLiant BL660c Gen9 Server
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
Problems Fixed:
- Critical issue for all UEFI systems using 2.2 TB or greater volumes configured with GPT partitions. For additional information please refer to the customer advisory # c04602001
- When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk drives in the system, the controller might go into a degraded mode and cease to function. A 0x0E error message would display during POST on subsequent power cycle and in the Integrated Management Log (IML)
- The controller would report 0xE0 error to HP Smart Storage Administrator (HP SSA) and would cease to function when set to RAID 6 mode
- Intermittent SSD SATA 6G drive failures would occur when drive was configured in Bay 1 of HP ProLiant BL465 Gen8 Server
- Uncorrectable ECC errors would cause the controller to stop responding (Lockup 0x13). This version of Smart Array firmware properly calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory # c03755983
- The HP D2220sb Storage Blade is not recognized when configuring it with the HP ProLiant BL460c Gen9 Server Blade. For additional information please refer to the customer advisory # c04602866
]]>
已解决的问题:
- 修复了在HBA模式下在SATA驱动器上运行IO时,罕见的控制器挂起的问题。
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
Problems Fixed:
-
Fix for a rare controller hang when running IO to SATA drives when in HBA-mode.
]]>
修正された問題点:
-
HBAモードで、SATAドライブへのIOを実行する場合のまれなコントローラーのハングアップを修正します。
]]>
해결된 문제:
- 드물지만 HBA 모드에서 SATA 드라이브에 IO를 실행할 때 컨트롤러가 중단되는 문제를 해결했습니다.
]]>
修正的問題:
- 修正在 HBA 模式中時執行 SATA 磁碟機 IO 時罕見的控制器當機的問題。
]]>
增强功能/新功能:
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
改善点/新しい機能:
]]>
향상된 기능/새로운 기능:
- 핫 플러그 이외 드라이브에 대한 지원을 추가했습니다.
]]>
Enhancements/New Features:
-
Added support for non-hotplug drives.
]]>
已解决的问题:
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
修正された問題点:
-
RAID 6モードに設定されたときにコントローラーはHP Smart Storage Administratorに0xE0エラーを報告し機能を中止しました。
-
HP ProLiant BL465 Gen8サーバーのベイ 1での断続的なSSD SATA 6Gドライブ障害。
-
訂正不能ECCエラーがコントローラーのハングアップを引き起こします(ロックアップ 0x13)。 Smartアレイファームウェアは、現在の論理ドライブ構成でストリーミング書き込み操作を維持するために必要な最大のコントローラーメモリ帯域幅を計算し、ピークのコントローラーメモリ帯域幅を必要としない構成で、キャッシュメモリ速度を削減します。 低速のメモリ速度で動作する場合、より少ない電力消費でパフォーマンスの低下はごくわずかであると予想されます。 詳しくは、以下のURLのカスタマーアドバイザリc03755983を参照してください。 http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
해결된 문제:
- 컨트롤러가 HP Smart Storage Administrator에 0xE0 오류를 보고하고 RAID 6 모드로 설정된 경우 작동을 중단합니다.
- HP ProLiant BL465 Gen8 서버의 베이 1에서 간헐적으로 SSD SATA 6g 드라이브 장애가 발생합니다.
- 컨트롤러 중단을 유발하는 수정 불가능한 ECC 오류(록업 0x13). Smart Array 펌웨어는 현재의 논리 드라이브 구성을 사용하여 쓰기 작업 스트리밍 유지에 필요한 최대 메모리 대역폭을 계산하여 최대 컨트롤러 메모리 대역폭이 필요 없는 구성에 대한 캐시 메모리 속도를 낮춥니다. 더 늦은 메모리 속도로 구동되는 경우 전력이 덜 소모되며 성능 저하는 무시해도 될 것으로 예상됩니다. 자세한 정보는 다음 URL을 통해 제공되는 고객 권고사항 c03755983을 참조하십시오. http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983.
]]>
Problems Fixed:
-
The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
-
Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
-
Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03755983
]]>
6.00 (B)的功能增强/新特性:
- 增加了对SUSE Linux Enterprise Server 12的支持
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
6.00 (B)の改善点/新しい機能:
-
SUSE Linux Enterprise Server 12のサポートを追加しました
]]>
6.00 (B)의 향상된 기능/새로운 기능:
- SUSE Linux Enterprise Server 12에 대한 지원 추가
]]>
Enhancements/New Features for 6.00 (B):
-
Added support for SUSE Linux Enterprise Server 12
]]>
6.00 版本修复的问题:
该版固件解决了以下问题:
- 在零内存RAID (ZMR) 模式下运行的系统上执行内核转储(kdump)时,控制器可能停止响应。
- HP智能阵列P420控制器连接到扩展背板和非扩展背板时,控制器不能正确控制SmartCarrier LED指示灯。
- Chkdsk运行缓慢。
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
バージョン6.00で修正された問題:
このファームウェアリリースは、次の問題を解決しました。
-
Zero Memory RAID (ZMR)モードで実行しているシステムでkdumpを実行すると、コントローラーは停止することがあります。
-
HP SmartアレイP420コントローラーがエキスパンダーバックプレーンと非エキスパンダーバックプレーンの両方に接続されたた場合、コントローラーはSmartCarrier LEDを正しく制御しません。
-
Chkdskの実行が遅かった。
]]>
버전 6.00에서 해결된 문제:
이 펌웨어 릴리스에서 다음과 같은 문제가 해결되었습니다.
- Zero Memory RAID(ZMR) 모드에서 실행 중인 시스템에 kdump를 실행할 때 컨트롤러가 정지할 수 있습니다.
- HP 스마트 어레이 P420 컨트롤러가 익스팬더 백플레인 및 비익스팬 더 백플레인 둘 다에 장착되어 있을 때, 컨트롤러가 SmartCarrier LED를 올바로 제어하지 않습니다.
- Chkdsk가 느리게 실행됩니다.
]]>
6.00 版中修正的問題:
此韌體版本已解決下列問題:
- 在零記憶體 RAID (ZMR) 模式中執行的系統上執行 kdump 時,控制器可能會暫停。
- HP Smart Array P420 控制器已連接至擴充背板與非擴充背板,控制器不會適當控制 SmartCarrier LED。
- Chkdsk 執行速度變慢。
]]>
6.00 版本修复的问题:
该版固件解决了以下问题:
- 在零内存RAID (ZMR) 模式下运行的系统上执行内核转储(kdump)时,控制器可能停止响应。
- HP智能阵列P420控制器连接到扩展背板和非扩展背板时,控制器不能正确控制SmartCarrier LED指示灯。
- Chkdsk运行缓慢。
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
Problems Fixed in version 6.00:
This firmware release resolved the following issues:
-
When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt.
-
When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs.
-
Chkdsk was running slowly.
]]>
バージョン6.00で修正された問題:
このファームウェアリリースは、次の問題を解決しました。
-
Zero Memory RAID (ZMR)モードで実行しているシステムでkdumpを実行すると、コントローラーは停止することがあります。
-
HP SmartアレイP420コントローラーがエキスパンダーバックプレーンと非エキスパンダーバックプレーンの両方に接続されたた場合、コントローラーはSmartCarrier LEDを正しく制御しません。
-
Chkdskの実行が遅かった。
]]>
버전 6.00에서 해결된 문제:
이 펌웨어 릴리스에서 다음과 같은 문제가 해결되었습니다.
- Zero Memory RAID(ZMR) 모드에서 실행 중인 시스템에 kdump를 실행할 때 컨트롤러가 정지할 수 있습니다.
- HP 스마트 어레이 P420 컨트롤러가 익스팬더 백플레인 및 비익스팬 더 백플레인 둘 다에 장착되어 있을 때, 컨트롤러가 SmartCarrier LED를 올바로 제어하지 않습니다.
- Chkdsk가 느리게 실행됩니다.
]]>
6.00 版中修正的問題:
此韌體版本已解決下列問題:
- 在零記憶體 RAID (ZMR) 模式中執行的系統上執行 kdump 時,控制器可能會暫停。
- HP Smart Array P420 控制器已連接至擴充背板與非擴充背板,控制器不會適當控制 SmartCarrier LED。
- Chkdsk 執行速度變慢。
]]>
增强功能/新功能:
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
Enhancements/New Features:
-
Ability to capture crash dump information.
]]>
改善点/新しい機能:
]]>
향상된 기능/새로운 기능:
]]>
增強或新增功能:
]]>
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
firmware:smartarray
103c
323b
103c
3352
103c
323b
103c
3351
103c
323b
103c
3354
103c
323b
103c
3350
103c
323b
103c
3355
103c
323b
103c
3353
103C
323B
103C
3356
CP026360.scexe
Wed, 18 Mar 2015 09:18:25
1.1
1
True
46a4d957a7
hp-firmware-smartarray-46a4d957a7
46a4d957a7
smartcomponent-linux-firmware-array
hp-firmware-smartarray-46a4d957a7
hp-firmware-smartarray-46a4d957a7
1.1
__ENDCPXML__ + " U aA큤m$$$$$mAm U U U U U U U U U U U U bd908a6ed216f6067f5df0b8888d2c16 e2f3d47eae8cf979e970f40eff0d4e5a 29f8271714c1e7f8911b87de2700f71c 84cec61cb752c2292415ea5e0406d727 d8a92969e089591ddca11219e2247bad 1ccac7d968e6bb34ac0c3bd3660d90c2 e21e4be18891137d40984fd8723e780a 4369d21c8f9b7b15f6075e762bd04df4 3382fda6e0e3541bf4f29e70cb293920 619c0c6b3819d77e27eacd573e2b0a0e root root root root root root root root root root root root root root root root root root root root root root root root hp-firmware-smartarray-46a4d957a7-6.34-1.1.src.rpm firmware(hp:firmware:3355103c) firmware(hp:firmware:3355103c) firmware(hp:firmware:3350103c) firmware(hp:firmware:3350103c) firmware(hp:firmware:3351103c) firmware(hp:firmware:3351103c) firmware(hp:firmware:3354103c) firmware(hp:firmware:3354103c) firmware(hp:firmware:3352103c) firmware(hp:firmware:3352103c) firmware(hp:firmware:3353103c) firmware(hp:firmware:3353103c) firmware(hp:firmware:3356103c) firmware(hp:firmware:3356103c) firmware(hp:firmware:d2220sb) firmware(hp:firmware:d2220sb) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003352bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003352bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003351bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003351bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003354bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003354bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003350bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003350bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003355bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003355bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003353bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003353bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003356bc*sc*i*) firmware(pci:v0000103Cd0000323Bsv0000103Csd00003356bc*sc*i*) hp-firmware-smartarray-46a4d957a7 hp-firmware-smartarray-46a4d957a7(x86-64)
@ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ rpmlib(VersionedDependencies) /bin/sh /bin/sh /bin/sh rpmlib(PayloadFilesHavePrefix) rpmlib(CompressedFileNames) /bin/bash /bin/sh libc.so.6()(64bit) libc.so.6(GLIBC_2.2.5)(64bit) libc.so.6(GLIBC_2.3)(64bit) libdl.so.2()(64bit) libdl.so.2(GLIBC_2.2.5)(64bit) libgcc_s.so.1()(64bit) libgcc_s.so.1(GCC_3.0)(64bit) libm.so.6()(64bit) libpthread.so.0()(64bit) libpthread.so.0(GLIBC_2.2.5)(64bit) libpthread.so.0(GLIBC_2.3.2)(64bit) libstdc++.so.6()(64bit) libstdc++.so.6(GLIBCXX_3.4.5)(64bit) libstdc++.so.6(GLIBCXX_3.4)(64bit) 3.0.3-1 4.0-1 3.0.4-1 4.8.1 Tl@TG@TFJTD@TCTBV@SϣSR@HP Linux Development 6.12 HP Linux Development 6.10 HP Linux Development 6.10 HP Linux Development 6.00-2 HP Linux Development 6.00-2 HP Linux Development 6.00-2 HP Linux Development 6.00 HP Linux Development 3.58 - *Problems Fixed:**
* Fix for a rare controller hang when running IO to SATA drives when in HBA-mode. - *Problems Fixed:**
* The controller would report 0xE0 error to HP Smart Storage Administrator and would cease to function when set to RAID 6 mode.
* Intermittent SSD SATA 6G drive failure in Bay 1 of the HP ProLiant BL465 Gen8 Server.
* Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Smart Array firmware calculates the maximum controller memory bandwidth required to sustain streaming write operations with the current logical drive configuration and reduces the cache memory speed on configurations that do not require peak controller memory bandwidth. When running at the slower memory speed, less power is consumed and performance degradation is expected to be negligible. For additional information, reference Customer Advisory c03755983 at the following URL: