{
    "DeviceClass": "aa148d2e-6e09-453e-bc6f-63baa5f5ccc4", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "System BIOS - U71", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "U71_1.70_04_02_2026.signed.flash", 
                        "InstallDurationSec": 300, 
                        "Order": 1, 
                        "PLDMImage": false, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": false, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "00000000-0000-0000-0000-000000000264", 
                "Version": "v1.70 (04/02/2026)"
            }, 
            {
                "DeviceName": "System BIOS - U71", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "U71_1.70_04_02_2026.signed.flash", 
                        "InstallDurationSec": 300, 
                        "Order": 1, 
                        "PLDMImage": false, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": false, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "00000000-0000-0000-0000-000000000273", 
                "Version": "v1.70 (04/02/2026)"
            }, 
            {
                "DeviceName": "System BIOS - U71", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "U71_1.70_04_02_2026.signed.flash", 
                        "InstallDurationSec": 300, 
                        "Order": 1, 
                        "PLDMImage": false, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": false, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "00000000-0000-0000-0000-000000000289", 
                "Version": "v1.70 (04/02/2026)"
            }
        ]
    }, 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "BIOS - System ROM"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "67116459", 
                "DateModified": "2026-04-07T02:55:15", 
                "FileList": [
                    "U71_1.70_04_02_2026.signed.flash"
                ], 
                "MD5Sum": "2e39a26bdd51807c69890e85df0972e1", 
                "Name": "U71_1.70_04_02_2026.fwpkg", 
                "Release": "2026-04-07T02:51:16", 
                "Revision": "", 
                "SHA1Sum": "483e20d96e5c9ab1f643f792c121f77c36a64c8b", 
                "SHA256Sum": "6af3963215f304ed6b0f5fb73aba3a01175f3ea2331d31a5a8047297a589fa74", 
                "Size": "64.01MB", 
                "TargetGUIDs": [
                    "00000000-0000-0000-0000-000000000264", 
                    "00000000-0000-0000-0000-000000000273", 
                    "00000000-0000-0000-0000-000000000289"
                ], 
                "TypeOfChange": "1", 
                "Version": "1.70_04-02-2026"
            }
        ], 
        "Id": {
            "Product": "f724e16e8d864d8e83739edbeda8aea6", 
            "Version": "f2111f331b0e4ccfbc192aa21f33ce37"
        }, 
        "Installation": {
            "Command": "cpqsetup.exe", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "yes"
            }, 
            "PerDeviceInstallTimeSeconds": 300, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "yes", 
            "RebootRequirement": "Required"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO7_IP_Address&gt; -u &lt;iLO7_username&gt; -p &lt;iLO7_password&gt;</em></strong></p>\n\n<p>Place the json file in the same folder as the fwpkg file.<br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "ROM Flash Firmware Package - HPE ProLiant Compute DL320/DL340/DL340e Gen12 (U71) Servers"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "11000"
            }, 
            "SupportedDevices": [], 
            "SupportedOperatingSystems": [
                {
                    "Major": "0", 
                    "Minor": "0", 
                    "Name": "Cross Operating System", 
                    "Platform": "oi", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "7", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 7.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 8.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2026-04-13T12:45:20", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p>Updated HPE branding logo to reflect the new HPE corporate identity.</p><p>Added new RBSU option to configure the Intel Platform Communications Technology (PCT) feature for PCT-capable processors.</p>", 
                        "Fixes": "<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with Intel Birch Stream UPLR3 and UPLR3.5 BKC updates.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p>\n<p><p>To streamline content and avoid duplication across documents, starting the Gen12 platform, the UEFI Workload Based Profiles and Tuning Guide has been deprecated, and the contents of this document are now available as part of the current UEFI System Utilities User Guide for HPE Compute Gen12 servers based on iLO7 (<a href=\"https://hpe.com/support/UEFIG12-iLO7-UG-en\">https://hpe.com/support/UEFIG12-iLO7-UG-en</a>).</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might hang at the memory initialization stage when reading crash logs.</p><p>Addressed an issue where the power-off action initiated from OneView could fail, causing the server profile not to be processed as expected.</p><p>Addressed an issue where NVMe drives could produce duplicate boot option entries after OS installation due to physical location information being incorrectly included in the structured string.</p><p>Addressed an issue where the iLO One-Time Boot option was not cleared after the selected boot target was launched.</p><p>Addressed an issue where the Intel PTAT tool could fail to launch. </p><p>Addressed an issue where system crash log–related information could not be exported from AHS logs.</p><p>Addressed an issue where system device names in RBSU might be incorrect in Japanese-language mode.</p><p><strong>Known Issues:</strong></p>None", 
                        "Lang": "en"
                    }
                ], 
                "Version": "1.70_04-02-2026"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p>Enabled Priority Core Turbo (PCT) feature support,</p>", 
                        "Fixes": "<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with Intel VROC v.9.3 updates.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p>\n<p><p>To streamline content and avoid duplication across documents, starting the Gen12 platform, the UEFI Workload Based Profiles and Tuning Guide has been deprecated, and the contents of this document are now available as part of the current UEFI System Utilities User Guide for HPE Compute Gen12 servers based on iLO7 (<a href=\"https://hpe.com/support/UEFIG12-iLO7-UG-en\">https://hpe.com/support/UEFIG12-iLO7-UG-en</a>).</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Address an issue where the system reports “266 – Non-Volatile Memory Corruption Detected in the IML logs.</p><p></p><p>Address an issue where the system Asset Tag can be modified even when Asset Tag Protection is set to Locked.</p><p></p><p>Address an issue where the system logs correctable errors as Uncorrectable Machine Check Exceptions in the IML and AHS.</p><p></p><p>Address an issue where the system reports incorrect slot information for NVMe devices when the PCIe link cannot train to its maximum supported speed.  </p><p></p><p>Address an issue where the system cannot enter the RBSU menu after Intel VMD/VROC is enabled.</p><p></p><p>Address an issue where the system reports an “Unsupported DIMM Configuration error when Granite Rapids XCC processors are installed with a 2-DIMM configuration.</p><p></p><p>Address an issue where certain devices are incorrectly configured with 10-bit TLP tags even though they do not support this feature.</p><p></p><p>Address an issue where incorrect OCP E610 NIC information is displayed in the RBSU one-time boot menu and PCIe device information (DL380a).</p><p><strong>Known Issues:</strong></p>None", 
                        "Lang": "en"
                    }
                ], 
                "Version": "1.62_02-06-2026"
            }
        ], 
        "SWKeys": [
            {
                "Name": "U71", 
                "SWKeyExpectedPath": "firmware:system"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL340 Gen12 Server"
            }, 
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL320 Gen12 Server"
            }, 
            {
                "Family": "FTP", 
                "Model": "FTP-Only System"
            }, 
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL340e Gen12"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "ComboFirmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}